The UOP-Specified Combustion Control Ametek Thermox WDG-IV UOP WDG-V UOP Oxygen Analyzers are precision instruments designed for oxygen measurement in refinery furnaces and hydrocarbon processing environments. Combining the reliability of zirconia sensor technology with UOP-specific engineering, these analyzers deliver unmatched accuracy for continuous catalyst regeneration (CCR) and flue gas monitoring. The dual-model system supports both low-concentration oxygen detection (WDG-IV) and in-situ flue gas analysis (WDG-V), ensuring optimal combustion control and emissions compliance.
Parameter | WDG-IV UOP Specification | WDG-V UOP Specification |
---|---|---|
Measurement Principle | Zirconia net oxygen sensor | In-situ zirconia probe |
Range | 0-1% to 0-100% O₂ | 0-1% to 0-25% O₂ |
Accuracy | ±0.75% of reading or ±0.05% O₂ | ±0.5% of reading or ±0.01% O₂ |
Response Time | <5 seconds (90% step) | <3 seconds (90% step) |
Power Requirements | 115/230 VAC, 47-63 Hz | 100-240 VAC, 50/60 Hz |
Output Signals | 4-20 mA, HART | 4-20 mA, Modbus RTU, HART, Foundation Fieldbus |
Safety Certification | SIL-2 certified | SIL-2 certified |
UOP-Specific Engineering: Tailored for UOP Continuous Catalyst Regeneration (CCR) processes and refinery furnace applications.
Dual-Mode Capability: WDG-IV for low-concentration O₂ detection; WDG-V for in-situ flue gas monitoring.
Advanced Diagnostics: Predictive maintenance alerts, self-calibration, and fault detection via integrated HMI.
Robust Construction: High-temperature resistant probes and corrosion-resistant enclosures for harsh environments.
Digital Integration: Seamless connectivity with DCS/PLC systems via HART, Modbus, and Foundation Fieldbus.
Refinery Furnaces: Optimizes air-fuel ratios for efficient combustion and reduced NOx emissions.
UOP CCR Platforming: Precision O₂ control during catalyst regeneration to prevent over-oxidation.
Sulfur Recovery Units: Monitors oxygen levels for optimal Claus process performance.
Ethylene & Hydrogen Production: Ensures gas purity and process safety in steam crackers and reformers.
Power Generation: Supports combustion control in coal, gas, and biomass power plants.